Desenvolvimento de um objeto simulador acessório para verificação dos indicadores de tamanho de campo no controle de qualidade em aceleradores lineares
| dc.contributor.advisor | Müller, Juliana dos Santos | |
| dc.contributor.advisor-co | Silva, Charlene da | |
| dc.contributor.advisor-coID | https://orcid.org/0000-0003-0761-4358 | |
| dc.contributor.advisor-coLattes | http://lattes.cnpq.br/6391581824898079 | |
| dc.contributor.advisorID | https://orcid.org/0000-0002-8593-304X | |
| dc.contributor.advisorLattes | http://lattes.cnpq.br/5040031883898616 | |
| dc.contributor.author | Müller, Daniela Maria | |
| dc.contributor.author | Miranda, Tainah Oliveira e | |
| dc.contributor.authorLattes | http://lattes.cnpq.br/3914894419198824 | |
| dc.contributor.authorLattes | http://lattes.cnpq.br/4198820584177781 | |
| dc.contributor.referee1 | Savi, Matheus Brum Marques Bianchi | |
| dc.contributor.referee1ID | https://orcid.org/0000-0001-9231-3570 | |
| dc.contributor.referee1Lattes | http://lattes.cnpq.br/1553763879090568 | |
| dc.contributor.referee2 | Monção, Maurício Mitsuo | |
| dc.contributor.referee2ID | https://orcid.org/0000-0003-0183-1992 | |
| dc.contributor.referee2Lattes | http://lattes.cnpq.br/6711064029343815 | |
| dc.date.accessioned | 2026-10-23T11:36:35Z | |
| dc.date.available | 2026-10-23T11:36:35Z | |
| dc.date.issued | 2022-07-20 | |
| dc.description.abstract | A radioterapia é uma modalidade de tratamento médico que faz uso da radiação ionizante para atingir a cura ou controle de uma neoplasia. Nesse tipo de tratamento, a energia depositada por meio de radiação gera um dano sistemático na massa tumoral até atingir a perda da função reprodutiva do clone tumoral ou a morte do tecido doente. Por se tratar de um recurso terapêutico de alta complexidade e de necessidade de precisão na execução do tratamento, é fundamental a aplicação de um controle de qualidade rigoroso em todos os equipamentos. Os testes necessários durante a realização do controle de qualidade costumam envolver o uso de equipamentos e acessórios de aferição. Sendo assim, o objetivo deste estudo é desenvolver um objeto simulador para o uso no controle de qualidade para os testes mecânicos em aceleradores lineares do Setor de Radioterapia. O desenho de estudo desta pesquisa foi uma abordagem quantitativa do tipo experimental exploratória descritiva. Na fase exploratória, foram feitas visitas ao setor de radioterapia, a fim de acompanhar os processos que envolvem a execução dos testes do controle de qualidade diário, principalmente os testes mecânicos, escopo deste estudo. A partir desta observação foi modelado, no software fusion 360, um protótipo do acessório complementar para utilização nos testes mecânicos. Para produção do acessório, utilizou-se como base uma placa de mdf de 3mm de espessura onde foi marcado a laser os tamanhos de campo, isocentro e réguas e inseriu-se marcadores radiopacos impressos em impressora 3D. Realizaram-se testes de funcionalidade nos protótipos até que fosse aprovado todas as características para a produção do objeto simulador, sendo possível constatar a competência do acessório simulador no teste proposto. A partir da pesquisa realizada foi possível constatar que as recomendações sobre o controle de qualidade em radioterapia identificam as necessidades dos profissionais frente a realização dos testes do campo luminoso e coincidência de campos de luz- radiação. Por fim, enfatiza-se a necessidade dos pesquisadores de realizarem mais aplicações da tecnologia de impressão 3D na área da saúde. | |
| dc.description.abstract | Radiotherapy is a medical treatment modality that makes use of ionizing radiation to achieve the cure or control of a neoplasm. In this type of treatment, the energy deposited by means of radiation generates systematic damage to the tumor mass until it reaches the loss of reproductive function of the tumor clone or the death of the diseased tissue. Because it is a highly complex therapeutic resource and requires precision in the execution of the treatment, it is essential to apply a rigorous quality control in all equipment. The tests required during quality control usually involve the use of gauging equipment and accessories. Therefore, the objective of this study is to develop a phantom for use in quality control for mechanical tests in linear accelerators in the Radiotherapy Sector. The study design of this research was a quantitative approach of the descriptive exploratory experimental type. In the exploratory phase, visits were made to the radiotherapy sector, in order to monitor the processes that involve the execution of daily quality control tests, mainly the mechanical tests, scope of this study. From this observation, a prototype of the complementary accessory was modeled in the fusion 360 software for use in the mechanical tests. For the production of the accessory, a 3mm thick mdf board was used as a basis, where the field, isocenter and ruler sizes were laser marked and radiopaque markers printed on a 3D printer were inserted. Functionality tests were carried out on the prototypes until all the characteristics for the production of the simulator object were approved, and it was possible to verify the competence of the simulator accessory in the proposed test. From the research carried out, it was possible to verify that the recommendations on quality control in radiotherapy in addition to identifying the needs of professionals in the face of carrying out the tests of the luminous field and coincidence of light-radiation fields. Finally, it emphasizes the need for researchers to apply 3D printing technology in healthcare. | |
| dc.identifier.citation | MÜLLER, Daniela Maria; MIRANDA, Tainah Oliveira e. Desenvolvimento de um objeto simulador acessório para verificação dos indicadores de tamanho de campo no controle de qualidade em aceleradores lineares. 2022. Trabalho de Conclusão de Curso (Superior de Tecnologia em Radiologia) – Instituto Federal de Santa Catarina, Florianópolis, 2022 | |
| dc.identifier.uri | https://repositorio.ifsc.edu.br/handle/1/2800 | |
| dc.language.iso | Português Brasil | pt_BR |
| dc.publisher | Instituto Federal de Santa Catarina | pt_BR |
| dc.publisher.country | Brasil | pt_BR |
| dc.publisher.department | Câmpus Florianópolis | pt_BR |
| dc.publisher.initials | IFSC | pt_BR |
| dc.publisher.program | Superior de Tecnologia em Radiologia | pt_BR |
| dc.rights.access | Acesso Aberto | |
| dc.subject | Radioterapia | |
| dc.subject | Controle de qualidade | |
| dc.subject | Impressão tridimensional | |
| dc.subject.cnpq | CIENCIAS DA SAUDE | |
| dc.title | Desenvolvimento de um objeto simulador acessório para verificação dos indicadores de tamanho de campo no controle de qualidade em aceleradores lineares | |
| dc.type | Trabalho de conclusão de graduação | pt_BR |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- Daniela_Maria_Muller - Tainah_Oliveira_e_Miranda - TCC.pdf
- Tamanho:
- 1.33 MB
- Formato:
- Adobe Portable Document Format
Licença do Pacote
1 - 1 de 1
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed to upon submission
- Descrição: