Análise da variação do número de Hounsfield em função do diâmetro em diferentes materiais para impressão 3D

dc.contributor.advisorSavi, Matheus Brum Marques Bianchi
dc.contributor.advisor-coAndrade, Marco Antônio Bertoncini
dc.contributor.advisor-coIDhttps://orcid.org/0000-0002-7262-2410
dc.contributor.advisor-coLatteshttp://lattes.cnpq.br/6107911850299107
dc.contributor.advisorIDhttps://orcid.org/0000-0001-9231-3570
dc.contributor.advisorLatteshttp://lattes.cnpq.br/1553763879090568
dc.contributor.authorSerafim, Nathália Regina
dc.contributor.authorLatteshttp://lattes.cnpq.br/3416982935306557
dc.contributor.referee1Soares, Flavio Augusto Penna
dc.contributor.referee1IDhttps://orcid.org/0000-0002-2668-7627
dc.contributor.referee1Latteshttp://lattes.cnpq.br/1128235541236010
dc.contributor.referee2Huhn, Andrea
dc.contributor.referee2IDhttps://orcid.org/0000-0002-4348-9374
dc.contributor.referee2Latteshttp://lattes.cnpq.br/2167651436297038
dc.date.accessioned2026-11-10T10:46:34Z
dc.date.available2026-11-10T10:46:34Z
dc.date.issued2025-07-28
dc.description.abstractA pesquisa tem como objetivo avaliar como o diâmetro e o material do preenchimento das peças influenciam nos valores de Hounsfield (HU) em phantoms produzidos por impressão 3D. A proposta é criar phantoms acessíveis e de baixo custo voltados para ensino e pesquisa em radiologia contribuindo para reduzir custos, evitar a exposição humana à radiação e melhorar a formação e capacitação de profissionais da área. Através de um estudo quantitativo e experimental é avaliado a variação do HU em peças 3D com diferentes diâmetros e materiais de preenchimento. O trabalho envolve a modelagem digital do corpo de prova e a impressão das peças utilizando filamentos ABS e XCT, seguido pelo preenchimento dessas peças com materiais variados como resinas epóxi e de poliuretano, espuma expansiva e de poliuretano (PU) estrutural. As peças impressas e preenchidas foram então submetidas à tomografia computadorizada no aparelho Canon Aquilion One localizado no Hospital Infantil Joana de Gusmão, parceiro IFSC, onde foram realizadas varreduras horizontais e verticais das peças. A avaliação das imagens foi realizada por meio da análise de Regiões de Interesse (ROIs) com formato circular, posicionadas em diferentes áreas da amostra seguindo os pontos cardeais, utilizando o software WEASIS. Também foram utilizadas ROIs lineares, orientadas nas direções horizontal e vertical, por meio do software ImageJ, a fim de complementar a análise espacial da distribuição de densidade. Os dados obtidos foram organizados e representados graficamente com o auxílio do software OriginPro. A análise dos gráficos apresentou como resultado que, grande parte dos materiais demonstrou maior instabilidade nos valores de HU na primeira camada, com posterior estabilização e uniformidade nas camadas superiores.
dc.description.abstractThe research aims to evaluate how the diameter and filling material of the parts influence the Hounsfield (HU) values in phantoms produced by 3D printing. The proposal is to create accessible, low-cost phantoms for teaching and research in radiology, contributing to reducing costs, avoiding human exposure to radiation, and improving the training and qualification of professionals in the field. Through a quantitative and experimental study, the variation in HU in 3D parts with different diameters and filling materials is evaluated. The work involves digital modeling of the test piece and printing of the parts using ABS and XCT filaments, followed by filling these parts with various materials such as epoxy and polyurethane resins, expanding foam, and structural polyurethane (PU). The printed and filled parts were then subjected to computed tomography on the Canon Aquilion One device located at the Joana de Gusmão Children's Hospital, an IFSC partner, where horizontal and vertical scans of the parts were performed. The images were evaluated by analyzing circular Regions of Interest (ROIs) positioned in different areas of the sample following the cardinal points, using WEASIS software. Linear ROIs, oriented in the horizontal and vertical directions, were also used, using ImageJ software, to complement the spatial analysis of density distribution. The data obtained were organized and represented graphically with the aid of OriginPro software. Analysis of the graphs showed that most of the materials exhibited greater instability in HU values in the first layer, with subsequent stabilization and uniformity in the upper layers.
dc.identifier.citationSERAFIM, Nathália Regina. Análise da variação do número de Hounsfield em função do diâmetro em diferentes materiais para impressão 3D. 2025. Trabalho de Conclusão de Curso (Superior de Tecnologia em Radiologia) – Instituto Federal de Santa Catarina, Florianópolis, 2025
dc.identifier.urihttps://repositorio.ifsc.edu.br/handle/1/2865
dc.language.isoPortuguês Brasilpt_BR
dc.publisherInstituto Federal de Santa Catarinapt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCâmpus Florianópolispt_BR
dc.publisher.initialsIFSCpt_BR
dc.publisher.programSuperior de Tecnologia em Radiologiapt_BR
dc.rights.accessAcesso Aberto
dc.subjectImpressão tridimensional
dc.subjectTomografia
dc.subjectProteção radiológica
dc.subject.cnpqCIENCIAS DA SAUDE
dc.titleAnálise da variação do número de Hounsfield em função do diâmetro em diferentes materiais para impressão 3D
dc.typeTrabalho de conclusão de graduaçãopt_BR

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Nathalia_Regina_Serafim - TCC.pdf
Tamanho:
7.34 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed to upon submission
Descrição: