Estudo experimental das distâncias mínimas em ramais de esgoto: uma análise aplicada às zonas de sobrepressão conforme a NBR 8160

dc.contributor.advisorJaques, Reginaldo Campolino
dc.contributor.advisorIDhttps://orcid.org/0000-0003-2595-7346
dc.contributor.advisorLatteshttp://lattes.cnpq.br/2160289884020501
dc.contributor.authorKretzer, Mateus José
dc.contributor.referee1Prim, Elivete Carmen Clemente
dc.contributor.referee1Latteshttp://lattes.cnpq.br/4532827366706566
dc.contributor.referee2Lima, Ricardo Clemente de
dc.contributor.referee2Latteshttp://lattes.cnpq.br/2439245752511134
dc.date.accessioned2026-04-09T12:08:41Z
dc.date.available2026-04-09
dc.date.available2026-04-09T12:08:41Z
dc.date.issued2025-12-18
dc.description.abstractA norma NBR 8160 estabelece os critérios técnicos que devem ser seguidos no projeto e na execução de instalações sanitárias em edificações, com o objetivo de prevenir o surgimento de patologias no sistema. De acordo com diversas pesquisas e levantamentos técnicos, as patologias hidrossanitárias figuram entre as mais recorrentes no ambiente da construção civil, tanto em edificações novas quanto em reformas. Dentre essas, destaca-se o problema do retorno de espuma em caixas sifonadas, frequentemente causado pela ligação inadequada de ramais de esgoto em zonas de sobrepressão, o que caracteriza uma falha de execução associada ao descumprimento das recomendações normativas. Diante disso, torna-se evidente a importância do cumprimento rigoroso das diretrizes estabelecidas pela NBR 8160 para garantir o desempenho funcional e a salubridade das instalações sanitárias. Contudo, observa-se que a norma, embora estabeleça determinados parâmetros, como distâncias mínimas e zonas críticas de pressão, não explicita, em alguns casos, a origem técnica ou experimental desses valores normatizados. Essa lacuna pode gerar dúvidas e dificuldades para os projetistas, especialmente em situações de maior complexidade ou restrição espacial, abrindo espaço para questionamentos e estudos mais aprofundados sobre a aplicabilidade e fundamentação de tais diretrizes. Considerando esse contexto, o presente trabalho tem como objetivo principal a análise prática dos efeitos provocados por ligações em zonas de sobrepressão, conforme descritas no item 4.2.4.3 da NBR 8160. Para isso, será construído um protótipo experimental que permitirá avaliar, de forma empírica, o comportamento do sistema frente a diferentes configurações de ligação, contribuindo para o entendimento técnico do fenômeno e oferecendo subsídios que possam auxiliar na interpretação e, eventualmente, na revisão dos critérios normativos vigentes.
dc.description.abstractThe NBR 8160 standard establishes the technical criteria that must be followed in the design and execution of sanitary instal- lations in buildings, aiming to prevent the occurrence of patholo- gies within the system. According to various studies and techni- cal surveys, plumbing pathologies are among the most recurrent issues in the construction sector, both in new buildings and in renovation projects. Among these, one of the most notable pro- blems is the return of foam in floor drains, often caused by the improper connection of sewage branches in overpressure zo- nes, a construction flaw associated with noncompliance with the normative recommendations. Given this, the importance of strict adherence to the guidelines established by NBR 8160 becomes evident in ensuring the functional performance and sanitary sa- fety of plumbing systems. However, it is observed that the stan- dard, while defining certain parameters such as minimum distan- ces and critical pressure zones, does not always specify the technical or experimental basis for these standardized values. This gap can create uncertainty and difficulties for designers, es- pecially in cases involving higher complexity or spatial constra- ints, thus opening the door for further questioning and deeper studies regarding the applicability and rationale of such guideli- nes. Considering this context, the present study aims primarily to conduct a practical analysis of the effects caused by connec- tions in overpressure zones, as described in item 4.2.4.3 of NBR 8160. To this end, an experimental prototype will be constructed to empirically assess the system’s behavior under different con- nection configurations, contributing to the technical understan- ding of the phenomenon and providing insights that may assist in the interpretation and, eventually, revision of the current nor- mative criteria.
dc.identifier.citationKRETZER, Mateus José. Estudo experimental das distâncias mínimas em ramais de esgoto: uma análise aplicada às zonas de sobrepressão conforme a NBR 8160. Trabalho de Conclusão de Curso (Bacharelado em Engenharia Civil) – Instituto Federal de Santa Catarina, Florianópolis, 2025.
dc.identifier.urihttps://repositorio.ifsc.edu.br/handle/1/868
dc.language.isoPortuguês Brasilpt_BR
dc.publisherInstituto Federal de Santa Catarinapt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentFlorianópolispt_BR
dc.publisher.initialsIFSCpt_BR
dc.publisher.programBacharelado em Engenharia Civilpt_BR
dc.rights.accessAcesso Aberto
dc.subjectInstalações hidráulicas e sanitárias
dc.subjectABNT NBR 8160
dc.subjectZonas de sobrepressão
dc.subject.cnpqENGENHARIAS
dc.titleEstudo experimental das distâncias mínimas em ramais de esgoto: uma análise aplicada às zonas de sobrepressão conforme a NBR 8160
dc.typeTrabalho de conclusão de graduaçãopt_BR

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Mateus_Jose_Kretzer - TCC.pdf
Tamanho:
4.03 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed to upon submission
Descrição: