Dimensionamento de contenção do tipo gabião em região de solo residual na cidade de Biguaçu/SC

dc.contributor.advisorSilva, Fábio Krueger da
dc.contributor.advisorIDhttps://orcid.org/0000-0002-4388-2491
dc.contributor.advisorLatteshttp://lattes.cnpq.br/4530487869192215
dc.contributor.authorPossato, Ana Paula Luz
dc.contributor.authorLatteshttp://lattes.cnpq.br/2513605113906589
dc.contributor.referee1Schuch, Fernanda Simoni
dc.contributor.referee1IDhttps://orcid.org/0000-0001-5776-7091
dc.contributor.referee1Latteshttp://lattes.cnpq.br/8913356598111378
dc.contributor.referee2Cordeiro, Rafael Fabiano
dc.contributor.referee2Latteshttp://lattes.cnpq.br/3792843523322922
dc.date.accessioned2026-06-30T10:30:32Z
dc.date.available2026-06-30T10:30:32Z
dc.date.issued2021-09-13
dc.description.abstractEsta pesquisa apresenta o dimensionamento de um muro de contenção do tipo gabião com base na caracterização geotécnica de um solo residual na cidade de Biguaçu/SC. A descrição física do solo foi obtida através dos resultados de ensaios de granulometria, densidade real dos grãos, limites de liquidez e plasticidade, compactação. A caracterização mecânica embasou-se a partir dos ensaios de expansão, determinação do CBR e cisalhamento direto. O solo residual foi classificado como um silte argiloso, desuniforme, mal graduado e altamente plástico. A modelagem do talude, muro de gabião e análises de estabilidade foram feitas por meio do software GEO5 da Fine Softwares. Foram apresentadas seis propostas de geometria para o muro de gabião, mas apenas três delas obtiveram resultados satisfatórios quanto a estabilidade interna, global e fundação. Conclui-se que a geometria 1 foi a estrutura que obteve o menor volume de construção conjunto a fatores de segurança satisfatórios.
dc.description.abstractThis research presents the sizing of a gabion-type retaining wall based on the geotechnical characterization of a residual soil in the city of Biguaçu/SC. The physical description of the soil was obtained through the results of granulometric tests, real grain density, liquidity and plasticity limits, compaction. The mechanical characterization was based on expansion tests, determination of CBR and direct shear. The residual soil was classified as clayey, uneven, poorly graded and highly plastic soil. Glacis modeling, gabion wall and stability analysis were performed using Fine Softwares GEO5 software. Six geometry proposals for the gabion wall were presented, but only three of them obtained satisfactory results in terms of internal and global stability and foundation. It is concluded that geometry 1 was the structure that obtained the smallest construction volume with satisfactory safety factors.
dc.identifier.citationPOSSATO, Ana Paula Luz. Dimensionamento de contenção do tipo gabião em região de solo residual na cidade de Biguaçu/SC. 2021. Trabalho de Conclusão de Curso (Bacharelado em Engenharia Civil) – Instituto Federal de Santa Catarina, Florianópolis, 2021
dc.identifier.urihttps://repositorio.ifsc.edu.br/handle/1/1820
dc.language.isoPortuguês Brasilpt_BR
dc.publisherInstituto Federal de Santa Catarinapt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCâmpus Florianópolispt_BR
dc.publisher.initialsIFSCpt_BR
dc.publisher.programBacharelado em Engenharia Civilpt_BR
dc.rights.accessAcesso Aberto
dc.subjectDimensionamento geotécnico
dc.subjectSolo - Uso
dc.subjectConstrução civil
dc.subject.cnpqENGENHARIAS
dc.titleDimensionamento de contenção do tipo gabião em região de solo residual na cidade de Biguaçu/SC
dc.typeTrabalho de conclusão de graduaçãopt_BR

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Ana_Paula_Luz_Possato - TCC.pdf
Tamanho:
4.16 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed to upon submission
Descrição: