Avaliação de vestimentas de proteção radiológica para energias utilizadas em medicina nuclear
| dc.contributor.advisor | Camozzato, Tatiane Sabriela Cagol | |
| dc.contributor.advisor-co | Yoriyaz, Hélio | |
| dc.contributor.advisor-coID | https://orcid.org/0000-0003-4023-236X | |
| dc.contributor.advisor-coLattes | http://lattes.cnpq.br/2359603996065755 | |
| dc.contributor.advisorID | https://orcid.org/0000-0002-3530-718X | |
| dc.contributor.advisorLattes | http://lattes.cnpq.br/0471800071296555 | |
| dc.contributor.author | Petry, Emanuely Amandia | |
| dc.contributor.authorLattes | http://lattes.cnpq.br/3713238403390352 | |
| dc.contributor.referee1 | Soares, Flavio Augusto Penna | |
| dc.contributor.referee1ID | https://orcid.org/0000-0002-2668-7627 | |
| dc.contributor.referee1Lattes | http://lattes.cnpq.br/1128235541236010 | |
| dc.contributor.referee2 | Souza, Daiane Cristini Barbosa de | |
| dc.contributor.referee2ID | https://orcid.org/0000-0001-6511-8024 | |
| dc.contributor.referee2Lattes | http://lattes.cnpq.br/9869274693276532 | |
| dc.contributor.referee3 | Carvalho, Jose Willegaignon de Amorim de | |
| dc.contributor.referee3Lattes | http://lattes.cnpq.br/3479378420355633 | |
| dc.date.accessioned | 2026-10-21T13:55:04Z | |
| dc.date.available | 2026-10-21T13:55:04Z | |
| dc.date.issued | 2022-05-06 | |
| dc.description.abstract | Na medicina nuclear são utilizadas fontes radioativas não seladas, o que pode resultar em maior exposição e contaminação de IOEs. O uso de VPR pelos profissionais da MN têm sido questionados, uma vez que a interação dos fótons com a composição dos aventais pode causar radiação de freamento ou efeito fotoelétrico. Comprometendo a proteção radiológica do IOE. Nesse contexto, o objetivo é analisar a eficiência das blindagens, avaliando a interação da radiação com a composição dos aventais de chumbo. Dessa forma respondendo a seguinte questão de pesquisa: “As VPRs utilizadas pelos IOEs em MN são eficientes em relação à energia dos radionuclídeos utilizados no SMN?” Para isto, se avaliou um avental de chumbo disponível em um SMN do sul do Brasil. Tendo como tipo de pesquisa investigativa experimental de análise quantitativa, em que também obteve-se simulações computacionais com método Monte Carlo por meio do software MCNP6. Os testes experimentais foram realizados com fontes, avental e detectores. Os RNs selecionados como fontes foram: 131I, 99mTc e FDG-18F. Observou-se aumento de captação nos valores de energia para radiação espalhada, em torno de 80 a 100 keV, com todos os radioisótopos e distâncias. Não obteve-se resultados tão eficientes para 131I e FDG-18F, visto que são RN com energias maiores, notando-se então maior radiação espalhada ao uso do avental. Visto nos testes experimentais e simulações, o avental consegue barrar fótons de baixa energia, porém para fótons de alta energia (como maiores que 140 keV) se torna menos eficiente. Ocorre o aumento de contagens na região antes do fotopico de cada RN, demonstrando a radiação espalhada. A diferença de dose equivalente foi menor com o teste com FDG-18F, comprovando que energias maiores a blindagem torna-se ineficaz. | |
| dc.description.abstract | In nuclear medicine, unsealed radioactive sources are used, which may result in increased exposure and contamination of OEIs. The use of radiological protective clothes by NM professionals has been questioned, since the interaction of photons with the composition of the aprons may cause braking radiation or photoelectric effect. Compromising the radiological protection of the OEI. In this context, the objective is to analyze the efficiency of shielding, evaluating the interaction of radiation with the composition of lead aprons. Thus answering the following research question: "Are the radiological protective clothes used by OEIs in NM efficient in relation to the energy of the radionuclides used in the NMS?" For this, a lead apron available in a NMS in southern Brazil was evaluated. The type of research was experimental with quantitative analysis, in which computational simulations were also obtained with the Monte Carlo method using the MCNP6 software. The experimental tests were performed with sources, apron and detectors. The RNs selected as sources were: 131I, 99mTc and FDG-18F. Increased uptake was observed in the energy values for scattered radiation, around 80 to 100 keV, with all radioisotopes and distances. Results were not as efficient for 131I and FDG-18F, since they are RNs with higher energies, thus noting greater scattered radiation when using the apron. As seen in the experimental tests and simulations, the apron is able to block low energy photons, but for high energy photons (such as larger than 140 keV) it becomes less efficient. Increased counts occur in the region before the photopeak of each RN, demonstrating the scattered radiation. The equivalent dose difference was smaller with the FDG-18F test, proving that higher energies the shielding becomes ineffective. | |
| dc.identifier.citation | PETRY, Emanuely Amandia. Avaliação de vestimentas de proteção radiológica para energias utilizadas em medicina nuclear. 2022. Dissertação (Mestrado Profissional em Proteção Radiológica) – Instituto Federal de Santa Catarina, Florianópolis, 2022. | |
| dc.identifier.uri | https://repositorio.ifsc.edu.br/handle/1/2779 | |
| dc.language.iso | Português Brasil | pt_BR |
| dc.publisher | Instituto Federal de Santa Catarina | pt_BR |
| dc.publisher.country | Brasil | pt_BR |
| dc.publisher.department | Câmpus Florianópolis | pt_BR |
| dc.publisher.initials | IFSC | pt_BR |
| dc.publisher.program | Mestrado Profissional em Proteção Radiológica | pt_BR |
| dc.rights.access | Acesso Aberto | |
| dc.subject | Medicina nuclear | |
| dc.subject | Proteção radiológica | |
| dc.subject | Radiação | |
| dc.subject | Higiene do trabalho | |
| dc.subject.cnpq | CIENCIAS DA SAUDE::MEDICINA::RADIOLOGIA MEDICA | |
| dc.title | Avaliação de vestimentas de proteção radiológica para energias utilizadas em medicina nuclear | |
| dc.type | Dissertação | pt_BR |
