Um estudo experimental sobre chuveiros, aterramentos e choque elétrico

dc.contributor.advisorFagundes, Saimon Miranda
dc.contributor.advisorLatteshttp://lattes.cnpq.br/2137223908849947
dc.contributor.authorNascimento, José Celso Vicente do
dc.contributor.referee1Silva, Paulo Cesar da
dc.contributor.referee1IDhttps://orcid.org/0000-0003-1807-5193
dc.contributor.referee1Latteshttp://lattes.cnpq.br/0728971002477871
dc.contributor.referee2Bortoluzzi, Adilson Pacheco
dc.contributor.referee2Latteshttp://lattes.cnpq.br/7999038999822796
dc.date.accessioned2026-08-24T14:34:04Z
dc.date.available2026-08-24T14:34:04Z
dc.date.issued2026-07-06
dc.description.abstractEste Trabalho de Conclusão de Curso apresenta um estudo experimental comparativo sobre o comportamento de chuveiros elétricos em três condições distintas de aterramento: aterramento TT, ausência total de aterramento e uso do neutro como aterramento (e sua simulação de rompimento). O objetivo central é analisar as consequências elétricas de cada cenário, considerando a tensão 220 volts, fenômenos de tensão fantasma, riscos de fuga de corrente e o desempenho do interruptor diferencial residual (IDR). Foram realizadas medições práticas entre registro e condutores do circuito, com o chuveiro em funcionamento nas condições de registro aberto, com IDR, utilizando lâmpada como carga de teste para verificação de tensão com possibilidade fuga de corrente ou tensão fantasma. No cenário sem aterramento, observou-se elevada presença de tensões fantasmas resultantes de acoplamentos capacitivos internos, além de fuga de correntes correlacionados a ausência de aterramento. O sistema neutro como aterramento cria uma falsa sensação de segurança, pois qualquer falha ou rompimento no neutro pode energizar partes metálicas expostas (como o próprio registro do chuveiro), ampliando significativamente os riscos ao usuário. Por outro lado, o aterramento TT adequadamente executado eliminou tensões fantasmas perceptíveis, reduziu praticamente a zero as correntes de fuga observadas e se mostrou o único cenário capaz de garantir caminhos seguros para correntes de falha, especialmente quando associado ao IDR. A análise também demonstrou que, apesar de essencial, o IDR não impede totalmente choques de pequena intensidade, menores de 30mA.
dc.description.abstractThis Final Course Project presents a comparative experimental study on the behavior of electric showers under three distinct grounding conditions: TT grounding, complete absence of grounding, and the use of the neutral conductor as grounding (including its simulated interruption). The main objective is to analyze the electrical consequences of each scenario, considering a 220-volt supply, phantom voltage phenomena, current leakage risks, and the performance of the residual current device (RCD). Practical measurements were carried out between the faucet valve and the circuit conductors, with the shower operating under open-valve conditions and protected by an RCD, using an incandescent lamp as a test load to verify the presence of voltage associated with either current leakage or phantom voltage. In the ungrounded scenario, a significant presence of phantom voltages resulting from internal capacitive coupling was observed, as well as leakage currents correlated with the absence of grounding. The use of the neutral conductor as grounding creates a false sense of safety, since any failure or interruption of the neutral conductor may energize exposed metallic parts (such as the shower faucet valve itself), significantly increasing the risks to the user. On the other hand, a properly implemented TT grounding system eliminated perceptible phantom voltages, reduced the observed leakage currents to virtually zero, and proved to be the only scenario capable of providing safe paths for fault currents, especially when associated with an RCD. The analysis also demonstrated that, although essential, the RCD does not completely prevent low-intensity electric shocks below 30 mA.en
dc.identifier.citationNASCIMENTO, José Celso Vicente do. Um estudo experimental sobre chuveiros, aterramentos e choque elétrico. 2026. Trabalho de Conclusão de Curso (Bacharelado em Engenharia Elétrica) – Instituto Federal de Santa Catarina, Itajaí, 2026.
dc.identifier.urihttps://repositorio.ifsc.edu.br/handle/1/2341
dc.language.isoPortuguês Brasilpt_BR
dc.publisherInstituto Federal de Santa Catarinapt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentCâmpus Itajaípt_BR
dc.publisher.initialsIFSCpt_BR
dc.publisher.programBacharelado em Engenharia Elétricapt_BR
dc.rights.accessAcesso Aberto
dc.subjectChuveiros elétricos
dc.subjectCoque elétrico
dc.subjectAterramento
dc.subjectInstalações elétricas - Requisitos de segurança
dc.subject.cnpqENGENHARIAS::ENGENHARIA ELETRICA::CIRCUITOS ELETRICOS, MAGNETICOS E ELETRONICOS
dc.titleUm estudo experimental sobre chuveiros, aterramentos e choque elétrico
dc.typeTrabalho de conclusão de graduaçãopt_BR

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
José_Celso_Vicente_do_Nascimento - TCC.pdf
Tamanho:
3.14 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed to upon submission
Descrição: