Controle de qualidade da argamassa de hidratação controlada em obra ao longo do tempo de armazenamento

dc.contributor.advisorPeruch, Juliana Machado Casali
dc.contributor.advisorIDhttps://orcid.org/0000-0002-8583-9395
dc.contributor.advisorLatteshttp://lattes.cnpq.br/9639458520971536
dc.contributor.authorMüller, Kamilly
dc.contributor.authorIDhttps://orcid.org/0009-0005-5948-4710
dc.contributor.authorLatteshttp://lattes.cnpq.br/9658624272705490
dc.contributor.referee1Calçada, Luciana Maltez
dc.contributor.referee1IDhttps://orcid.org/0000-0002-2978-1942
dc.contributor.referee1Latteshttp://lattes.cnpq.br/6502797069607275
dc.contributor.referee2Oliveira, Alexandre Lima
dc.contributor.referee2IDhttps://orcid.org/0009-0005-0954-3196
dc.contributor.referee2Latteshttp://lattes.cnpq.br/6588306695770934
dc.date.accessioned2026-04-13T11:34:23Z
dc.date.available2026-04-13
dc.date.available2026-04-13T11:34:23Z
dc.date.issued2025-07-29
dc.description.abstractO controle de qualidade da argamassa de hidratação controlada não se limita à fabricação do produto, mas também abrange o recebimento em obra e suas propriedades ao longo do tempo de armazenamento. Apesar das orientações citadas em normativas brasileiras e muitos autores abordarem a temática da argamassa de hidratação controlada, a indústria da construção civil ainda carece de especificações e padronização nos procedimentos que envolvem esse produto. Sendo assim, o objetivo deste trabalho foi avaliar o controle de qualidade, em obra, sobre a argamassa de hidratação controlada ao longo do tempo de armazenamento. Foram avaliados 25 lotes de argamassa na obra e laboratório, nos estados fresco e endurecido, em 0 hora e 24 horas. Ao analisar os dados obtidos, observou-se que os três tipos de argamassa, provenientes de dois fabricantes, apresentaram de maneira geral comportamentos semelhantes na maioria dos ensaios. Entretanto, as amostras analisadas não se mantiveram estáveis durante o período de armazenamento. Outro ponto observado foi que existem, de fato, diferenças na consistência e perda de trabalhabilidade da argamassa ao longo do tempo, porém esse comportamento não é constante. O presente estudo buscou demonstrar a viabilidade de se realizar ensaios em obra a favor dos controle de qualidade da argamassa de hidratação controlada, com foco na análise de consistência. Mostrou-se mais eficaz o método de penetração da régua, por ser mais sensível do que slump teste, como critério de aceitação no recebimento da argamassa.
dc.description.abstractQuality control of ready mix mortar is not limited to the product's manufacture, but also encompasses its receipt at the construction site and its properties during storage. Despite the guidelines cited in Brazilian regulations and many authors addressing the topic of ready mix mortar, the construction industry still lacks specifications and standardization in procedures involving this product. Therefore, the objective of this study is to evaluate the quality control of ready mix mortar on site during storage. A total of 25 batches of mortar were evaluated on-site and in the laboratory, in both fresh and hardened states, at 0 hours and 24 hours. Analysis of the data revealed that the three types of mortar, from two manufacturers, generally exhibited similar behavior in most tests. However, the tested samples did not yield results during the storage period. Another point observed was that there are indeed differences in the consistency and loss of workability of the mortar over time, but this behavior is not constant. This study sought to demonstrate the benefits of conducting on-site tests for the quality control of ready mix mortar, focusing on consistency analysis. The ruler coverage method proved to be more effective, as it was more sensitive than the slump test, as range rewards in mortar collection.
dc.identifier.citationMÜLLER, Kamilly. Controle de qualidade da argamassa de hidratação controlada em obra ao longo do tempo de armazenamento. Trabalho de Conclusão de Curso (Bacharelado em Engenharia Civil) – Instituto Federal de Santa Catarina, Florianópolis, 2025.
dc.identifier.urihttps://repositorio.ifsc.edu.br/handle/1/907
dc.language.isoPortuguês Brasilpt_BR
dc.publisherInstituto Federal de Santa Catarinapt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentFlorianópolispt_BR
dc.publisher.initialsIFSCpt_BR
dc.publisher.programBacharelado em Engenharia Civilpt_BR
dc.rights.accessAcesso Aberto
dc.subjectArgamassa
dc.subjectGestão da qualidade total
dc.subjectHidratação controlada
dc.subject.cnpqENGENHARIAS
dc.titleControle de qualidade da argamassa de hidratação controlada em obra ao longo do tempo de armazenamento
dc.typeTrabalho de conclusão de graduaçãopt_BR

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Kamilly_Muller - TCC.pdf
Tamanho:
8.01 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed to upon submission
Descrição: